Products & Services

For businesses and industries of every size that need backup power and want to cut peaks at start-up times

C&I Battery Storage

Energy storage for factories and businesses

C&I (Commercial & Industrial) batteries differ from home batteries in size, cooling and safety standards. They are used to cut Demand Charges, shift consumption from On-Peak to Off-Peak, back up production lines and store surplus solar for the night. EV Power Energy installs two main platforms: Huawei and Sigenergy

Huawei

LUNA2000-215 / 241 Series Smart String ESS

Pre-built 215–241 kWh cabinet with built-in PCS

Smart String architecture manages energy at pack level, so each battery pack works independently and the weakest pack never drags down the whole system. Hybrid Cooling, pack-level oxygen-cutoff fire suppression and directional gas venting, with Grid Forming mode for microgrids and Black Start

Capacity per cabinet
215 kWh (215-2S10) / 241 kWh (241-2S1)
Cell technology
LFP 314Ah · 240S1P · 4 packs per cabinet
System PCS
PCS2000-108K-MB1, 108 kW · 3-phase 380/400/415V
Charge/discharge rate
Up to 0.5 CP
Round-trip efficiency
Up to 91.3%
DoD
0–100%
Cooling
Hybrid Cooling
Operating temperature
-30°C to 55°C
Safety systems
Pack-level oxygen-cutoff fire suppression · directional gas venting · top pressure relief vent
Certificates
UL9540A · IEC 62933-5-1/2
Cabinet size
1,150 × 1,800 × 2,100 mm · up to 2.8 t
Key features
Grid Forming · Active Balancing · automatic SOC calibration · adjustable Power Factor
Sigenergy

SigenStack (BAT 12.0) + Sigen C&I Inverter

Modular 12 kWh, expandable 48–253 kWh per system

Built from 12 kWh modules stacked 4–21 high, so you can size precisely to your real load instead of buying an oversized cabinet, and expand later without changing the existing setup. DC-coupled, with separate fire suppression for every 12 kWh and smart air cooling that needs less maintenance than liquid cooling

Capacity per module
12.006 kWh
System size
4–21 modules = 48–253 kWh per system
Cell technology
LFP (LiFePO₄)
Charge/discharge rate
Normal 0.5C · peak up to 1C
Maximum power
Charge/discharge up to 126 kW
Paired inverter
Sigen C&I Inverter 50 / 60 / 80 / 100 / 110 / 125 kW
Inverter efficiency
Up to 98.6%
Cooling
Smart Air Cooling
Water/dust rating
IP66 for both battery and inverter
Safety systems
Independent fire suppression for every 12 kWh module
Installation
Floor-standing, 4–7 modules per column
Key features
DC-coupled · built-in EMS · expand later without dismantling the system

Huawei or Sigenergy — what's the difference?

TopicsHuaweiSigenergy
System conceptPre-built cabinet with fixed 215/241 kWh capacityModular 12 kWh, scalable 48–253 kWh
Best forLarge, well-defined loads needing high capacity from day oneLoads still evolving, or expanding step by step
CoolingHybrid CoolingSmart Air Cooling
Fire suppressionPack-level, oxygen cutoffIndependent for every 12 kWh module
Grid Forming / microgridSupportedCheck by inverter model
Expanding laterAdd cabinetsAdd modules
Operating temperature-30°C to 55°CPer model datasheet

What can a C&I battery do?

Cut Demand Charges

Discharge the battery when the factory draws peak power, lowering the Peak Demand used to calculate the monthly bill

Shift consumption (TOU arbitrage)

Charge during cheap Off-Peak hours and discharge during more expensive On-Peak hours

Store surplus solar

Store daytime solar you don't need for the evening and night instead of wasting it

Back up production lines

Keep power flowing during outages, reducing losses from stopped lines and process waste

Reduce generator use

Replace or cut diesel generator hours, saving fuel and maintenance

Support ESG goals

Raise the share of clean energy actually used in the factory, with historical data for reporting

System videos

Overview of Huawei's C&I solution

The SigenStack modular concept

Interview on strengths and limitations

Real installation steps from the manufacturer

* Figures are taken from manufacturer datasheets. Actual designs always require a Load Profile Analysis and Site Survey first

Business batteries
All sizes
Backup power
Peak Demand
Cut

For factories and businesses, Demand Charges from power spikes when machines start up are a hard cost to control. A battery system shaves those peaks by discharging when the load is highest

Beyond cutting bills, the system backs up production processes that can't stop, preventing damage and lost revenue from sudden outages

Scales from small businesses to heavy industry, with an energy management system (EMS) that schedules charging and discharging for maximum benefit

Service highlights

  • ✓Shave Peak Demand to cut Demand Charges
  • ✓Backup for production lines that can't stop
  • ✓Scales from SMEs to heavy industry
  • ✓Smart energy management with EMS
Register

Get a special price offer

Free consultation and site survey! ROI calculated before you decide

LINE